The Bryan Cervical Disc: wear properties and early clinical results.

TitelThe Bryan Cervical Disc: wear properties and early clinical results.
Publication TypeJournal Article
Year of Publication2004
AuthorsAnderson, PA, Sasso, RC, Rouleau, JP, Carlson, CS, Goffin, J
JournalThe spine journal : official journal of the North American Spine Society
Volume4
Issue6 Suppl
Pagination303S-309S
Date Published2004 Nov-Dec
ISSN1529-9430
SchlüsselwörterBandscheibenprothese
Abstract BACKGROUND CONTEXT: The rationale for motion preservation by disc replacement after anterior cervical discectomy is to diminish long-term morbidity secondary to adjacent segment degeneration. However, these disc prostheses will be subject to wear and its possible adverse consequences. PURPOSE: Assess the in vitro and in vivo wear properties of the Bryan Cervical Disc and the early clinical results. STUDY DESIGN: In vitro mechanical testing, caprine animal model and prospective European human trial. OUTCOME MEASURE: In vitro mechanical testing used American Society for Testing and Materials standards to measure wear rates and debris. Caprine results were analyzed by histopathologic analysis by a blinded veterinary pathologist. Clinical outcomes were measured by Odoms's criteria, independent radiologic analysis and Short Form-36. METHODS: In vitro wear testing in cervical spine simulator for up to 40 M cycles. Wear rates were determined and particles analyzed microscopically. The in vivo inflammatory response was studied in goats that had discectomy at C4-C5. They were sacrificed between 3 and 12 months and histopathologically were compared with controls who had fusions with titanium plates. A prospective clinical trial of 136 patients with minimum 1-year follow-up was analyzed using validated questionnaires and radiographs. RESULTS: In vitro wear averaged approximately 1.76% by weight at 10 M cycles and 18% at 40 M cycles. Wear debris were present in the periprosthetic tissues in 4 of 11 animals without inflammatory response. The early clinical results were satisfactory in over 90% of patients. CONCLUSION: The in vivo and in vitro wear properties are satisfactory for the expected duration of life of the prosthesis. The early clinical results are satisfactory and equal to fusion.
DOI10.1016/j.spinee.2004.07.026
Alternate JournalSpine J
Full Text
PubMed ID15541681
Folgen Sie der Gelenk-Klinik auf Facebook, Twitter oder Instagram

Bitte ein Gelenk wählen

Anatomische Struktur
Schulterschmerzen Ellenbogenschmerzen Hand und Handgelenk Huefte Wirbelsäule Hand Fuss Sprunkggelenk und Schmerzen im Knöchel Knieschmerzen und Schmerzen im Knöchel

Jobportal des Gelenk-Klinik MVZ

Wir haben Spaß an unserer Arbeit und möchten dich daran teilhaben lassen. Für unsere Klinikerweiterung in 2020 suchen wir daher Verstärkung:

Orthopädische Gelenk-Klinik

Anfahrt zur Orthopädischen Gelenk Klinik in Freiburg

Orthopädische Gelenk-Klinik
EndoprothetikZentrum (EPZ), Zentrum für Fuß und Sprunggelenkschirurgie (ZFS)

Tel: (0761) 55 77 58 0

Praxis Gundelfingen:
Alte Bundesstraße 58
79194 Gundelfingen

OP-Zentrum Freiburg:
Gundelfinger Straße 11
79108 Freiburg

OP-Zentrum Gundelfingen:
Alte Bundesstraße 29
79194 Gundelfingen

anfrage@gelenk-klinik.de