Wear analysis of the Bryan Cervical Disc prosthesis.

TitelWear analysis of the Bryan Cervical Disc prosthesis.
Publication TypeJournal Article
Year of Publication2003
AuthorsAnderson, PA, Rouleau, JP, Bryan, VE, Carlson, CS
JournalSpine
Volume28
Issue20
PaginationS186-94
Date Published2003 Oct 15
ISSN1528-1159
SchlüsselwörterBandscheibenprothese
Abstract STUDY DESIGN: In vitro wear testing of the Bryan Cervical Disc prosthesis was performed in a cervical spine simulator. The biologic response was assessed in chimpanzee and goat animal models. OBJECTIVE: Determine the wear characteristics of the Bryan disc. SUMMARY OF BACKGROUND DATA: Large joint arthroplasties fail most commonly by wear and consequent formation of particulate material, which induces an inflammatory response. Therefore, measuring the wear characteristics of the new spinal disc replacements is important. METHODS: Six prosthetic assembles were tested to 10 or 40 million cycles by load and motion and 3 additional assemblies were tested by load only in a cervical spine simulator. Any debris was examined using ASTM standards. The local biologic response to the prosthesis was examined in two chimpanzees. Nine goats were used to assess the biologic response in both local and distant tissues. Arthrodesis was performed on three additional control goats that received an allograft and an anterior cervical plate. RESULTS: Wear results: cervical spine simulators that applied the loads and motions associated with activities of daily living produced wear particulate at a rate of 1.2 mg per million cycles. Device height decreased 0.02 mm per million cycles with approximately 77% of this decrease due to gradual creep of the nucleus under the constant compressive load. Particles generated were granular in shape with a mean feret diameter of 3.9 microm. All animals tolerated placement of the Bryan disc. Wear debris was present in the periprosthetic and epidural spaces in some animals. However, no significant inflammatory response was observed. No wear material was found distant from the implant in draining lymph tissue, the liver, or the spleen. CONCLUSIONS: The Bryan disc has satisfactory wear characteristics and does not produce a significant inflammatory response.
DOI10.1097/01.BRS.0000092212.42388.79
Alternate JournalSpine
Full Text
PubMed ID14560190
Folgen Sie der Gelenk-Klinik auf Facebook, Twitter oder Instagram

Bitte ein Gelenk wählen

Anatomische Struktur
Schulterschmerzen Ellenbogenschmerzen Hand und Handgelenk Huefte Wirbelsäule Hand Fuss Sprunkggelenk und Schmerzen im Knöchel Knieschmerzen und Schmerzen im Knöchel

Jobportal des Gelenk-Klinik MVZ

Wir haben Spaß an unserer Arbeit und möchten dich daran teilhaben lassen. Für unsere Klinikerweiterung in 2020 suchen wir daher Verstärkung:

Orthopädische Gelenk-Klinik

Anfahrt zur Orthopädischen Gelenk Klinik in Freiburg

Orthopädische Gelenk-Klinik
EndoprothetikZentrum (EPZ), Zentrum für Fuß und Sprunggelenkschirurgie (ZFS)

Tel: (0761) 55 77 58 0

Praxis Gundelfingen:
Alte Bundesstraße 58
79194 Gundelfingen

OP-Zentrum Freiburg:
Gundelfinger Straße 11
79108 Freiburg

OP-Zentrum Gundelfingen:
Alte Bundesstraße 29
79194 Gundelfingen

anfrage@gelenk-klinik.de